• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³ .
• Electrical efficiency is based on cosphi =1.0 and ISO3046-1 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Remarks:
• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³ .
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Remarks:
• Above Gensets are based on 50Hz, 1000rpm, 400V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Remarks:
• Above Gensets are based on 60Hz, 1200rpm, 480V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Models List of MAN Natural Gas Gensets & CHPs (50Hz, 1500rpm) | |||||||||||
Model | Elec. Power (kWe) | Heat Output (kWt) | Engine Model | Engine Power (kW) | Cyls. & Type | Dspl. (L) | Elec. Eff. | Heat Eff. | Total Eff. | D/L | |
☆EM-35N5 | 35 | / | E0834E312 | 37 | 4.L | 4.6 | 32.0% | / | / | ||
EM-50N5 | 50 | 79 | E0834E302 | 54 | 4.L | 4.6 | 36.5% | 53.5% | 90.0% | ||
★EM-66N5 | 66 | 82 | E0834LE312 | 68 | 4.L | 4.6 | 37.0% | 46.0% | 83.0% | ||
EM-75N5 | 75 | 109 | E0836E302 | 75 | 6.L | 6.9 | 37.0% | 46.0% | 83.0% | ||
EM-100N5 | 100 | 132 | E0836LE302 | 110 | 6.L | 6.9 | 38.0% | 46.0% | 84.0% | ||
※EM-130N5 | 130 | 193 | E2676E302 | 140 | 6.L | 12.4 | 36.6% | 54.2% | 90.8% | ||
EM-150N5 | 150 | 207 | E2876E312 | 150 | 6.L | 12.8 | 38.3% | 52.8% | 91.1% | ||
EM-200N5 | 200 | 242 | E2876LE302 | 210 | 6.L | 12.8 | 37.2% | 48.9% | 86.1% | ||
EM-220N5 | 220 | 231 | E2676LE202 | 220 | 6.L | 12.4 | 43.4% | 46.8% | 90.2% | ||
EM-270N5 | 270 | 375 | E3262E302 | 275 | 12.V | 25.8 | 39.6% | 54.0% | 93.6% | ||
※EM-300N5 | 300 | 364 | E3268LE242 | 320 | 8.V | 17.2 | 39.1% | 47.5% | 86.6% | ||
EM-350N5 | 350 | 380 | E3268LE212 | 370 | 8.V | 17.2 | 41.9% | 52.5% | 94.4% | ||
EM-430N5 | 430 | 490 | E3262LE232 | 450 | 12.V | 25.8 | 39.6% | 44.6% | 84.2% | ||
EM-520N5 | 520 | 648 | E3262LE202 | 550 | 12.V | 25.8 | 38.8% | 48.3% | 87.1% | ||
EP-1000N5 | 1000 | 1250 | 4016-61TRS2 | 1042 | 16.V | 61.1 | 38.7% | 42.2% | 80.9% |
Remarks:
• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 500m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Models with "☆" for only power generation units; Models with "★" for only CHP(combined power and heat) units.
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Models List of MAN Natural Gas Gensets & CHPs (60Hz, 1800rpm)
| ||||||||||
Model | Elec. Power (kWe) | Heat Output (kWt) | Engine Model | Engine Power (kW) | Cyls. & Type | Dspl. (L) | Elec. Eff. | Heat Eff. | Total Eff. | D/L |
EM-50N6 | 50 | 79 | E0834E302 | 62 | 4.L | 4.6 | 34.0% | 49.0% | 83.0% | |
★EM-66N6 | 66 | 82 | E0834LE312 | 68 | 4.L | 4.6 | 37.0% | 46.0% | 83.0% | |
EM-80N6 | 80 | 109 | E0836E302 | 85 | 6.L | 6.9 | 37.0% | 46.0% | 83.0% | |
EM-100N6 | 100 | 132 | E0836LE302 | 110 | 6.L | 6.9 | 38.0% | 46.0% | 84.0% | |
EM-150N6 | 150 | 207 | E2876E312 | 170 | 6.L | 12.8 | 36.0% | 45.0% | 81.0% | |
EM-200N6 | 200 | 242 | E2876LE302 | 210 | 6.L | 12.8 | 37.2% | 46.0% | 83.2% | |
EM-220N6 | 220 | 231 | E2676LE202 | 250 | 6.L | 12.4 | 39.4% | 49.1% | 88.5% | |
☆EM-220N6 | 220 | / | E2876LE302 | 210 | 6.L | 12.8 | 37.2% | / | / | |
☆EM-250N6 | 250 | / | E2676LE202 | 250 | 6.L | 12.4 | 41.6% | / | / | |
EM-270N6 | 270 | 375 | E3262E302 | 300 | 12.V | 25.8 | 38.0% | 46.0% | 84.0% | |
※EM-300N6 | 300 | 364 | E3268LE242 | 300 | 8.V | 17.2 | 39.1% | 47.5% | 86.6% | |
EM-350N6 | 350 | 380 | E3268LE212 | 390 | 8.V | 17.2 | 39.9% | 45.0% | 84.9% | |
※EM-375N6 | 375 | 447 | E3268LE212 | 390 | 8.V | 17.2 | 39.2% | 45.0% | 84.2% | |
EM-430N6 | 430 | 524 | E3262LE232 | 450 | 12.V | 25.8 | 39.6% | 44.6% | 84.2% | |
EM-450N6 | 450 | 490 | E3262LE232 | 450 | 12.V | 25.8 | 39.6% | 44.6% | 84.2% | |
EM-520N6 | 520 | 648 | E3262LE202 | 580 | 12.V | 25.8 | 38.6% | 46.5% | 85.1% | |
EM-560N6 | 560 | 648 | E3262LE202 | 580 | 12.V | 25.8 | 38.6% | 46.5% | 85.1% |
Remarks:
• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 500m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Models with "☆" for only power generation units; Models with "★" for only CHP(combined power and heat) units.
• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Models List of MWM Natural Gas Gensets & CHP (50Hz, 1500rpm)
| ||||||||||
Model | Elec. Power (kWe) | Heat Output (kWt) | Engine Model | Engine Power (kW) | Cyls.& Type | Dspl. (L) | Elec Eff. | Heat Eff. | Total Eff. |
D/L |
※EW-400N5 | 400 | 404 | TCG3016V08/ CG132-8 | 436 | 8.V | 17.5 | 43.1% | 43.6% | 86.7% | |
EW-600N5 | 600 | 654 | TCG3016V12/ CG132-12 | 656 | 12.V | 26.3 | 43.3% | 44.6% | 87.9% | |
EW-800N5 | 800 | 858 | TCG3016V16/ CG132-16 | 820 | 16.V | 35.0 | 43.5% | 44.6% | 88.1% | |
EW-1000N5 | 1000 | 1100 | TCG3016V16S/ CG132-16S | 1000 | 16.V | 35.0 | 43.0% | 45.4% | 88.4% | |
※EW-1000N5 | 1000 | 1177 | TCG2020V12K/ CG170-12 | 1187 | 12.V | 53.1 | 43.0% | 45.4% | 88.4% | |
※EW-1125N5 | 1125 | 1253 | TCG2020V12K/ CG17-12 | 1187 | 12.V | 53.1 | 40.9% | 45.6% | 86.5% | |
EW-1200N5 | 1200 | 1189 | TCG2020V12/ CG170-12 | 1245 | 12.V | 53.1 | 43.6% | 43.3% | 86.9% | |
※EW-1500N5 | 1500 | 1675 | TCG2020V16K/ CG170-16 | 1557 | 16.V | 70.8 | 40.9% | 45.7% | 86.6% | |
EW-1560N5 | 1560 | 1576 | TCG2020V16/ CG170-16 | 1620 | 16.V | 70.8 | 43.2% | 43.8% | 87.0% | |
EW-2000N5 | 2000 | 2021 | TCG2020V20/ CG170-20 | 2079 | 20.V | 88.5 | 43.7% | 43.2% | 86.9% | |
※EW-2300N5 | 2300 | 2279 | TCG3020V20/ CG170-20 | 2387 | 20.V | 89.0 | 44.0% | 43.6% | 87.6% |
Remarks:
• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>70, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
Models List of MWM Natural Gas Gensets & CHP (60Hz, 1800rpm)
| ||||||||||
Model | Elec. Power (kWe) | Heat Output (kWt) | Engine Model | Engine Power (kW) | Cyls.& Type | Dspl. (L) | Elec Eff. | Heat Eff. | Total Eff. | D/L
|
※EW-400N6 | 400 | 427 | TCG3016V08/ CG132-V8 | 436 | 8.V | 17.5 | 42.1% | 45.0% | 87.1% | |
EW-600N6 | 600 | 654 | TCG3016V12/ CG132-V12 | 656 | 12.V | 26.3 | 42.4% | 45.7% | 88.1% | |
EW-800N6 | 800 | 856 | TCG3016V16/ CG132-V16 | 820 | 16.V | 35 | 42.6% | 45.5% | 88.1% | |
※EW-1000N6 | 1000 | 1100 | TCG2020V12K/ CG170-V12 | 1187 | 12.V | 53.1 | 40.7% | 45.6% | 86.3% | |
※EW-1125N6 | 1125 | 1261 | TCG2020V12K/ CG170-V12 | 1187 | 12.V | 53.1 | 40.7% | 45.6% | 86.3% | |
EW-1200N6 | 1200 | 1189 | TCG2020V12/ CG170-V12 | 1245 | 12.V | 53.1 | 43.4% | 43.2% | 86.6% | |
※EW-1500N6 | 1500 | 1686 | TCG2020V16K/ CG170-V16 | 1557 | 16.V | 70.8 | 40.6% | 45.7% | 86.3% | |
EW-1560N6 | 1560 | 1576 | TCG2020V16/ CG170-V16 | 1620 | 16.V | 70.8 | 43.0% | 43.8% | 86.8% | |
EW-2000N6 | 2000 | 2021 | TCG2020V20/ CG170-V20 | 2079 | 20.V | 88.5 | 43.4% | 43.2% | 86.6% |
Remarks:
• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.
• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>70, lower calorific value: LHV>36MJ/Nm³.
• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.
• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.
• For power deratings caused by other temps and altitudes, please consult Ettes Power.
• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.
• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).
• Special configurations for Soundproof Container, ATS and Synchronizing Parallel System are available for options.
• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options.
• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.
● PNG (Pipeline Natural Gas) | ● CNG(Compressed Natural Gas) |
● LNG (Liquid natural gas) | ● Oilfield APG (Associated Petroleum Gas) |
● Coalmine/ Coalbed Methane Gas | ● CBM (Coalbed Methane) |
● Well Gas | ● Marsh Gas |
● Shale Gas | ● Other Methane Based Gases |
Composition | Abbr. | Limits | Remarks |
Methane number | MN | >80 for natural gas | For Lower value, please consult ETTES POWER |
Calorific value | Hμ,N | Lower value of 36MJ/Nm³ | Standard Calorific Value for Ettes Datasheet as per ISO8528/1, ISO3046/1 and BS5514/1. |
Chlorine | CL | <80 mg / Nm³ CH4 | For higher value, please consult ETTES POWER |
Fluoride | F | <40 mg / Nm³ CH4 | For higher value, please consult ETTES POWER |
Total-chlorine Fluoride | ∑(Cl,F) | <80 mg / Nm³ CH4 | For higher value, please consult ETTES POWER |
Dust | / | <5μm or <10 mg / Nm³ CH4 | For higher value, please consult ETTES POWER |
Oil Vapor | / | <400 mg / Nm³ CH4 | No condensation may occur in the mixture section |
Silicon Element | Si | <2 mg / Nm³ CH4 | For higher value, please consult ETTES POWER |
Sulphur | S | <200 mg / Nm³ | For higher values, please consult ETTES POWER |
Hydrogen Sulphide | H2S | <200 ppm or <304 mg / Nm³ | For higher value, please consult ETTES POWER |
Ammonia | NH3 | <40 ppm or<30 mg / Nm³ | For other values, please consult ETTES POWER |
Gas Pressure Range | / | 5kPa~20kPa | For other values, please consult ETTES POWER |
Gas Temperature | / | <30℃ | For other values, please consult ETTES POWER |
Overseas Market Sales Dept.
Add: No 188, Anshan West Road, Nankai District, Tianjin, China
General Line: +86-22-23796980
Sales Line 01:+86-13672013688
Sales Line 02:+86-15620075781
FAX: +86-22-23796811
Email: sales@ettespower.com
ettespower@gmail.com
Skype No 1: ettespower
Skype No 2: ettes-power
Ettes Power Group © 2016 | All Rights Reserved | No 188, Anshan West Road, Tianjin, China | Tel: (86) 22-23796980 | Fax: (86) 22-23796811 | E-mail: info@ettespower.com
| Legal Notices | Privacy Policy | Sitemap|