Mitsubishi S16R Series

Genset Features



► About Ettes Diesel Generators

Ettes Power is the leading manufacturer and packager for complete diesel & gas generators from 20kW upto 3000kW. We can use world top engines (Cummins, Perkins, MTU, MAN, MWM, Deutz, CNPC 190 Series & Low speed 300 Series etc.) and other top quality materials to ASSEMBLE complete-generator-set. Ettes power generations enjoy hot markets in more than 70 countries all over the world including Latin America, Africa, Middle East, Europe and Asia markets. 

► About Mitsubishi Diesel Engines

Since 1917, Mitsubishi diesel and gas engines have excelled worldwide, ranking among the world’s largest industrial equipment producers, with merits of high reliable performance, high durability, long overhaul time, compact design, light weight, low fuel consumption, exceptionally quiet with high-efficiency combustion, worldwide warranty & service network etc, aiming to maximize the customer's operation cost saving. Mitsubishi Engines is one of your best choice for power generation. 


 Benefits of Ettes Mitsubishi Series Generators

• Wide power scope of generting sets from 500~2500kVa. 

• Advanved engine design, Low noise and low fuel consumption. 

• Overhaul can reach over 30000 hours, longer than other common levels. 

• Low emissions of CARB, EPA and CSA etc, enviroment friendly. 

• Strong warranty policy and technical support from ETTES POWER and Mitsubishi Global. 

• Worldwide guarantee and distribution network for spare parts and engine service.

• Top materials list for complete generator set assembling and fabrication.


Materials Items Brand & Specifications
Alternators Stamford AVK, Leroy Somer or Mec calte
Control System
Deepsea, ComAp or DEIF
Base Frame U-Steel Strong Baseframe
Air Circuit Breaker/Switchgear ABB, Schneider, Eaton or Siemens
Special Configuration

Common soundproof canopy

20 & 40 feet modular container

Weatherproof enclosure & trailer

ATS/ACS system (automatic transfer switch)

Synchronization parallel control panel

Remote control & Scada system

Oil & cylinder water heater

Anti-condensation heater (space heater)

Digital AVR, AREP/PMG system

IP44 protection level & B class temperature rise

High voltage alternator (3.3kV, 6.3kV, 10.5kV)

---




50Hz Models List

Models List of Mitsubishi Gensets (50Hz, 1500rpm)

Model

Prime Power Standby Power Engine Model

Max 

 Power 

(kW/Hp)

Cyls.&

Type

Dspl.

(liters)

Overall

Dimmension

(mm)

Weight

(kg)

PDF 

D/L

kW kVa kW kVa

ES-750

546

682

600

750

S6R2-PTA-C

635

6.L

TBA
3560*1420*2050 5150

ES-825

600

750

660

825

S6R2-PTAA-C  

710

6.L

TBA 4080*1715*2000 5650
ES-1375 1000 1250 1100 1375 S12R-PTA-C 1190 12.V TBA 4520*2200*2510 9850

ES-1500 1100 1375 1200 1500 S12R-PTA2-C 1285 12.V TBA 4520*2200*2510 9850
ES-1650 1200 1500 1320 1650 S12R-PTAA2-C 1404 12.V TBA 4920*2200*3000 12800

ES-1900 1392 1740 1520 1900 S16R-PTA-C 1590 16.V TBA 5470*2200*2550 13000
ES-2100 1520 1900 1680 2100 S16R-PTA2-C 1760 16.V TBA 5470*2200*2550 14500

ES-2250 1640 2050 1800 2250 S16R-PTAA2-C 1895 16.V TBA 5700*2400*2575 16000
ES-2500 1800 2250 2000 2500 S16R-PTAW 2167 16.V TBA 5985*2555*2775 17200

Remarks:

• Above gensets data are based on 50Hz, 1500RPM, 400V,3 Phases & 4 Wires, Power Factor 0.8.

• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.

• Special configurations for Soundproof Canopy & Container, ATS, Parallel Control and Remote Control are available for options.

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.


60Hz Models List

Models List of Mitsubishi Gensets (60Hz, 1800rpm)

Model

Prime Power Standby Power Engine Model

Max 

Power

(kW/Hp)

Cyls.&

Type

Dspl.

(liters)

Overall

Dimmension

(mm)

Weight

(kg)

PDF 

D/L

kW
kVa kW kVa
ES-600 435 544 480 600 S6A3-PTA-S TBA 6.L TBA 3560*1420*2050 4885
ES-625 460 575 500 625 S6A3-PTAA-S TBA 6.L TBA
3560*1420*2050 4885
ES-575 460 575 / / S6R-PTA TBA 6.L TBA 4080*1715*2000 5650
ES-788 570 713 630 788 S6R-PTA-S TBA 6.L TBA 4080*1715*2000 5650
ES-1088 790 988 870 1088 S12A2-PTA2-S TBA 12.V TBA 4225*1815*2360 7800
ES-1338 960 1200 1070 1338 S12H-PTA-S TBA 12.V TBA 4225*1815*2360 7800
ES-1150 920 1150 / / S12R-PTA TBA 12.V TBA 4520*2200*2510 9850
ES-1575 1150 1438 1260 1575 S12R-PTA-S TBA 12.V TBA 4520*2200*2510 9850
ES-1775 1280 1600 1420 1775 S12R-PTA2-S TBA 12.V TBA 4920*2200*3000 12800
ES-1563 1250 1563 / / S16R-PTA TBA 16.V TBA 5470*2200*2550 13000
ES-2125 1550 1938 1700 2125 S16R-PTA-S TBA 16.V TBA 5470*2200*2550 14500
ES-2375 1730 2163 1900 2375 S16R-PTA2-S TBA 16.V TBA 5700*2400*2575 16000
ES-2500 1800 2250 2000 2500 S16R-PTAA2 TBA 16.V TBA 5985*2555*2775 17200

Remarks:

• Above gensets data are based on 60Hz, 1800RPM, 440V,3 Phases & 4 Wires, Power Factor 0.8.

• Other low voltages and high voltage of 4.16 kV, 6.6kV and 13.8kV are available for options.

• Special configurations for Soundproof Canopy & Container, ATS, Parallel Control and Remote Control are available for options.

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.


Contact us

*