You are here: Home / Products / CHP-Cogeneration / Products-List of Natural Gas / CHP-Cogeneration / Products-List of Natural Gas

Ettes Power Solutions

Key-Products

Follow Us:

About ETTES Natural Gas Cogeneration

As a leading manufacture and supplier for gas engine generator and CHPs in China, ETTES products are ranking the global-first-class with advanced design, highly reliable quality and performance, convenient for operations & maintenance and all-around after sales service. ETTES Natural gas CCHP/Trigeneration are ranging from 20kW upto 2000kW, can be driven by world top engine brands of Cummins, Perkins, MAN, MWM and CNPC series, enjoying hot markets in more than 70 countries all over the world.
MAN MWM 500kW 1000kW container soundproof natural gas genset & cogeneration ETTES POWER
MAN MWM container soundproof natural gas biogas engine genrator set & CHP ETTES POWER
Heat recovery control system of MWM 600kW 800kW container biogas generator & CHP ETTES POWER
FAT Factory Testing for 2x500kW Cummins container natural gas generating set ETTES POWER
500kW Cummins container CNG compressed ntural gas fired generator set ETTES POWER
1000kW 1MW Perkins Container Natural gas engine Generator set & CHP ETTES POWER
MWM 600 kW 800kW farm biogas generating set & CHP cogeneration ETTES POWER
1000kW container PNG Pipeline Natural Gas oilfield gas generator set ETTES POWER
1000kW 1MW special container well gas powered generation in African desert ETTES POWER
1000kW 800kW Cummins Container oilfield gas generators for Transportation ETTES POWER
6MW 6×1000kW Coalmine Coalbed Methane Gas Natural Gas Engine Power Plant ETTESPOWER
Control & monitoring center for 1MW 2MW Cummins oilfield natural gas power plant ETTES POWER
7MW 7×1000kW APG Associated Petroleum Gas Natural Gas Engine Power Plant ETTESPOWER
1000kW 1MW APG associated petroleum gas generating set power plant ETTES POWER
Diesel & Gas Powered Generation Plant Oil Gas Field in Latin America ETTES POWER

Typical Diagram of Natural Gas Generator & CHP

Ettes Power Gas Engine Generators CHPs running diagram Ettespower Group

ECN-Cummins Natural Gas Generator Series

More >>
Ettes power Cummins diesel engine generating set genset Ettespower 100kva 200kva 300kva 400kva 500kva 600kva 800kva 1000kva
At power scope of 40kW~500kW, Ettes Cummins series natural gas powered generating set  & CHP (combined heat and power) units are driven by engines of 4B3.9, 6B5.9, 6C8.3, NT855, KT19, KT38 and KT50 etc, with merits of high reliable, quick installation, easy operation and low maintenance cost. Besides standard package of gas electrical generation (natural gas generator), client’s special requirements can be tailored such as CHP, CCHP, ATS, parallel operation system, remote monitor & control, modularized soundproof & weatherproof container.
 

Models List of Cummins Natural Gas Gensets & CHPs (50Hz, 1500rpm)
 
Model Elec. Power (kWe) Heat Output (kWt)

Engine

 Model

Engine Max Power (kW) Cyls. & Type Dspl.(L) Elec. Eff.  Heat Eff. Total Eff.

PDF

D/L

EC-30N5 30 45 4BTA3.9-G 45 4.L 3.9 32.5% 48.7% 81.2% click download pdf
EC-40N5 40 60 4BTA3.9-G 45 4.L 3.9 32.6% 48.9% 81.5% click download pdf
EC-60N5 60 90 6BTA5.9-G 100 6.L 5.9 32.8% 49.0% 81.8% click download pdf
EC-80N5 80 120 6BTA5.9-G 100 6.L 5.9 33.0% 49.1% 82.1% click download pdf
EC-100N5 100 145 6CTA8.3-G 145 6.L 8.3 33.6% 49.1% 82.7% click download pdf
EC-120N5 120 175 6CTA8.3-G 145 6.L 8.3 33.8% 49.2% 83.0% click download pdf
EC-180N5 180 251 NTA855-G 230 6.L 14 35.3% 49.3% 84.6% click download pdf
EC-200N5 200 277 NTA855-G 230 6.L 14 35.5% 49.3% 84.8% click download pdf
EC-280N5 280 351 KTA19-G 350 6.L 19 38.1% 47.8% 85.9% click download pdf
EC-300N5 300 375 KTA19-G 350 6.L 19 38.2% 47.8% 86.0% click download pdf
EC-450N5 450 556 KTA38-G 570 12.V 38 38.3% 48.2% 86.5% click download pdf
EC-500N5 500 627 KTA38-G 570 12.V 38 38.5% 48.3% 86.8% click download pdf
EC-800N5 800 982 K38N-G8 900 12.V 38 39.0% 47.9% 86.9% click download pdf
EC-1000N5 1000 1180 K50N-G10 1100 16.V 50 40.0% 47.2% 87.2% click download pdf
 
Remarks:

• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³ .

• Electrical efficiency is based on cosphi =1.0 and ISO3046-1 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

 


Models List of Cummins Natural Gas Gensets & CHPs (60Hz, 1800rpm)
 
Model Elec. Power (kWe) Heat Output (kWt) Engine Model  Engine Max Power (kW) Cyls. & Type Dspl.(L) Elec. Eff.  Heat Eff. Total Eff.

PDF

D/L

EC-30N6 30 45 4BTA3.9-G 45 4.L 3.9 32.5% 48.7% 81.2% click download pdf
EC-40N6 40 60 4BTA3.9-G 45 4.L 3.9 32.6% 48.9% 81.5% click download pdf
EC-60N6 60 90 6BTA5.9-G 100 6.L 5.9 32.8% 49.0% 81.8% click download pdf
EC-80N6 80 120 6BTA5.9-G 100 6.L 5.9 33.0% 49.1% 82.1% click download pdf
EC-100N6 100 145 6CTA8.3-G 145 6.L 8.3 33.6% 49.1% 82.7% click download pdf
EC-120N6 120 175 6CTA8.3-G 145 6.L 8.3 33.8% 49.2% 83.0% click download pdf
EC-180N6 180 251 NTA855-G 230 6.L 14 35.3% 49.3% 84.6% click download pdf
EC-200N6 200 277 NTA855-G 230 6.L 14 35.5% 49.3% 84.8% click download pdf
EC-280N6 280 351 KTA19-G 350 6.L 19 38.1% 47.8% 85.9% click download pdf
EC-300N6 300 375 KTA19-G 350 6.L 19 38.2% 47.8% 86.0% click download pdf
EC-450N6 450 556 KTA38-G 570 12.V 38 38.3% 48.2% 86.5% click download pdf
EC-500N6 500 627 KTA38-G 570 12.V 38 38.5% 48.3% 86.8% click download pdf
EC-800N6 800 982 K38N-G8 900 12.V 38 39.0% 47.9% 86.9% click download pdf
EC-1000N6 1000 1180 K50N-G10 1100 16.V 50 40.0% 47.2% 87.2% click download pdf
 

Remarks:

• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³ .

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

EJN-CNPC Natural Gas Generator Series

More >>
 
ETTESPOWER-CNPC-GAS-ENGINE-GENERATOR-SET-CHP-500KW-1000KW-1MW-ETTES-POWER
At power scope of 300kW~4000kW, Ettes CNPC series natural gas power generation & CHP (combined heat and power) units are driven by engine series of 6140, 12V190, H16V190 L20V190 and 16V26/32T etc, those gas fueled generaotor is with merits of big displacement, sufficient reserve-power, strong capability against load-surge, easy for installation & maintenance, long overhaul, vastly used in oil & gas fields, drilling plantform, coalmines and outside construction etc. It is the ideal solution for gas cogenertion & gas power plant to drive loads under harsh conditions of island operation.
 

 

Models List of CNPC Natural Gas Gensets & CHPs (50Hz, 1000rpm)

 

Model Elec. Power (kWe) Heat Output (kWt) Engine Model Engine Power (kW) Cyls. & Type Dspl.(L) Elec. Eff.  Heat Eff. Total Eff.

PDF

D/L

EJ-300N5 300 375 JC15DT 350 6.L 15 37.2% 46.5% 83.1% click download pdf
EJ-500N5 500 627 12V190ZDT 600 12.V 71 36.1% 45.3% 81.4% click download pdf
EJ-600N5 600 770 12V190ZL 660 12.V 71 37.0% 47.5% 84.5% click download pdf
EJ-700N5 700 903 12V190ZL 750 12.V 71 37.2% 48.0% 85.2% click download pdf
EJ-1200N5 1200 1416 H16V190ZLT 1320 16.V 97 38.3% 45.2% 83.5% click download pdf
EJ-2000N5 2000 2258 L20V190ZLT 2200 20.V 145 40.2% 45.4% 85.6% click download pdf
 

Remarks:

• Above Gensets are based on 50Hz, 1000rpm, 400V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

 

 

Models List of CNPC Natural Gas Gensets & CHPs (60Hz, 1200rpm)

 

 

Model Elec. Power (kWe) Heat Output (kWt) Engine Model Engine Power (kW) Cyls. & Type Dspl.(L) Elec. Eff.  Heat Eff. Total Eff.

PDF

D/L

EJ-300N6 300 375 JC15DT 350 6.L 15 37.2% 46.5% 83.1% click download pdf
EJ-500N6 500 627 12V190ZDT 600 12.V 71 36.1% 45.3% 81.4% click download pdf
EJ-600N6 600 770 12V190ZL 660 12.V 71 37.0% 47.5% 84.5% click download pdf
EJ-700N6 700 903 12V190ZL 750 12.V 71 37.2% 48.0% 85.2% click download pdf
EJ-1200N6 1200 1416 H16V190ZLT 1320 16.V 97 38.3% 45.2% 83.5% click download pdf
EJ-2000N6 2000 2258 L20V190ZLT 2200 20.V 145 40.2% 45.4% 85.6% click download pdf
 

Remarks:

• Above Gensets are based on 60Hz, 1200rpm, 480V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

EMN-MAN Natural Gas Generator Series

More >>
0
 
Ettes Power MAN Natural gas biogas engine generator CHPs Ettespower
At power scope of 60kW~560kW, Ettes MAN series natural gas electric generator & CHP units are driven by engine series of E0834, E0836, E2848, E2876, E2676, E3268 and E3262, with merits of compact design, high electrical and thermal efficiency, low consumption of gas fuel and lub oil, extended service intervals of over 50000 hours and low emissions due to state-of-the-art combustion technologies etc. MAN Series gas trigeneration is the ideal solutions for gas cogeneration, gas power station and other waste to energy projects, enjoying highly global reputation due to it's proven technology and highly reliable performance. 
 

Models List of MAN Natural Gas Gensets & CHPs (50Hz, 1500rpm)
 
Model Elec. Power (kWe) Heat Output (kWt) Engine Model Engine Power (kW) Cyls. & Type Dspl. (L) Elec. Eff. Heat Eff. Total Eff.

PDF

D/L

 
☆EM-35N5 35 / E0834E312 37 4.L 4.6 32.0% / / click download pdf  
EM-50N5 50 79 E0834E302 54 4.L 4.6 36.5% 53.5% 90.0% click download pdf  
★EM-66N5 66 82 E0834LE312 68 4.L 4.6 37.0% 46.0% 83.0% click download pdf  
EM-75N5 75 109 E0836E302 75 6.L 6.9 37.0% 46.0% 83.0% click download pdf  
EM-100N5 100 132 E0836LE302 110 6.L 6.9 38.0% 46.0% 84.0% click download pdf  
EM-130N5 130 193 E2676E302 140 6.L 12.4 36.6% 54.2% 90.8% click download pdf  
EM-150N5 150 207 E2876E312 150 6.L 12.8 38.3% 52.8% 91.1% click download pdf  
EM-200N5 200 242 E2876LE302 210 6.L 12.8 37.2% 48.9% 86.1% click download pdf  
EM-220N5 220 231 E2676LE202 220 6.L 12.4 43.4% 46.8% 90.2% click download pdf  
EM-270N5 270 375 E3262E302 275 12.V 25.8 39.6% 54.0% 93.6% click download pdf  
EM-300N5 300 364 E3268LE242 320 8.V 17.2 39.1% 47.5% 86.6% click download pdf  
EM-350N5 350 380 E3268LE212 370 8.V 17.2 41.9% 52.5% 94.4% click download pdf  
EM-430N5 430

490

E3262LE232 450 12.V 25.8 39.6% 44.6% 84.2% click download pdf  
EM-520N5 520 648 E3262LE202 550 12.V 25.8 38.8% 48.3% 87.1% click download pdf  
EP-1000N5 1000 1250 4016-61TRS2 1042 16.V 61.1 38.7% 42.2% 80.9% click download pdf  

Remarks:

• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 500m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Models with "☆" for only power generation units; Models with "★" for only CHP(combined power and heat) units.

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

 

 

Models List of MAN Natural Gas Gensets & CHPs (60Hz, 1800rpm)

 

Model Elec. Power (kWe) Heat Output (kWt) Engine Model Engine Power (kW) Cyls. & Type Dspl. (L) Elec. Eff. Heat Eff. Total Eff.

PDF

D/L

EM-50N6 50 79 E0834E302 62 4.L 4.6 34.0% 49.0% 83.0% click download pdf
★EM-66N6 66 82 E0834LE312 68 4.L 4.6 37.0% 46.0% 83.0% click download pdf
EM-80N6 80 109 E0836E302 85 6.L 6.9 37.0% 46.0% 83.0% click download pdf
EM-100N6 100 132 E0836LE302 110 6.L 6.9 38.0% 46.0% 84.0% click download pdf
EM-150N6 150 207 E2876E312 170 6.L 12.8 36.0% 45.0% 81.0% click download pdf
EM-200N6 200 242 E2876LE302 210 6.L 12.8 37.2% 46.0% 83.2% click download pdf
EM-220N6 220 231 E2676LE202 250 6.L 12.4 39.4% 49.1% 88.5% click download pdf
☆EM-220N6 220 / E2876LE302 210 6.L 12.8 37.2% / / click download pdf
☆EM-250N6 250 / E2676LE202 250 6.L 12.4 41.6% / / click download pdf
EM-270N6 270 375 E3262E302 300 12.V 25.8 38.0% 46.0% 84.0% click download pdf
※EM-300N6 300 364 E3268LE242 300 8.V 17.2 39.1% 47.5% 86.6% click download pdf
EM-350N6 350 380 E3268LE212 390 8.V 17.2 39.9% 45.0% 84.9% click download pdf
※EM-375N6 375 447 E3268LE212 390 8.V 17.2 39.2% 45.0% 84.2% click download pdf
EM-430N6 430 524 E3262LE232 450 12.V 25.8 39.6% 44.6% 84.2% click download pdf
EM-450N6 450 490 E3262LE232 450 12.V 25.8 39.6% 44.6% 84.2% click download pdf
EM-520N6 520 648 E3262LE202 580 12.V 25.8 38.6% 46.5% 85.1% click download pdf
EM-560N6 560 648 E3262LE202 580 12.V 25.8 38.6% 46.5% 85.1% click download pdf

 

Remarks:

• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>80, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 500m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Models with "☆" for only power generation units; Models with "★" for only CHP(combined power and heat) units.

• Special configurations for Soundproof Canopy & Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

 

EWN-MWM Natural Gas Generator Series

More >>
SS2Ettespower-Group-CAT-MWM-Gas-Engine-Generator-CCHP-800kW-1000kW-1MW-CHP-Ettes-Power
At power scope of 400kW~2300kW, Ettes MMW series gas fired generator & CCHP are driven by engines of TCG3016 (CG132), TCG2020 (CG170) and TCG2032 (CG260) series at cylinder config. of V8, V12, V16 and V20, with benefits of most compact design, highest optimized electrical efficiency (over 40%~43.7%), lowest consumption of gas fuel and lub oil, longest overhaul time over 64000 hours and low emissions levels due to advanced combustion technologies etc. MWM Series natural gas generator set, natural gas CHP System and natural gas cogeneration can be called the best solutions for gas power plant application all over the world.
 

 

Models List of MWM Natural Gas Gensets & CHP (50Hz, 1500rpm)

 

Model

Elec. Power

(kWe)

Heat Output

(kWt)

Engine Model

Engine Power

(kW)

Cyls.&

Type

Dspl.

(L)

Elec Eff. Heat Eff. Total Eff.

 

PDF

D/L

※EW-400N5 400 404

TCG3016V08/

CG132-8

436 8.V 17.5 43.1% 43.6% 86.7% click download pdf
EW-600N5 600 654

TCG3016V12/

CG132-12

656 12.V 26.3 43.3% 44.6% 87.9% click download pdf
EW-800N5 800 858

TCG3016V16/

CG132-16

820 16.V 35.0 43.5% 44.6% 88.1% click download pdf
EW-1000N5 1000 1100

TCG3016V16S/

CG132-16S

1000 16.V 35.0 43.0% 45.4% 88.4% click download pdf
※EW-1000N5 1000 1177

TCG2020V12K/

CG170-12

1187 12.V 53.1 43.0% 45.4% 88.4% click download pdf
※EW-1125N5 1125 1253

TCG2020V12K/

CG17-12

1187 12.V 53.1 40.9% 45.6% 86.5% click download pdf
EW-1200N5 1200 1189

TCG2020V12/

CG170-12

1245 12.V 53.1 43.6% 43.3% 86.9% click download pdf
※EW-1500N5 1500 1675

TCG2020V16K/

CG170-16

1557 16.V 70.8 40.9% 45.7% 86.6% click download pdf
EW-1560N5 1560 1576

TCG2020V16/

CG170-16

1620 16.V 70.8 43.2% 43.8% 87.0% click download pdf
EW-2000N5 2000 2021

TCG2020V20/

CG170-20

2079 20.V 88.5 43.7% 43.2% 86.9% click download pdf
※EW-2300N5 2300 2279

TCG3020V20/

CG170-20

2387 20.V 89.0 44.0% 43.6% 87.6% click download pdf
 

Remarks:

• Above Gensets are based on 50Hz, 1500rpm, 400V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.4kV, cosphi=1.0 for 50Hz, methane number of natural gas>70, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 3.3kV, 6.3kV and 10.5kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

 

 

Models List of MWM Natural Gas Gensets & CHP (60Hz, 1800rpm)

 

Model

Elec. Power

(kWe)

Heat Output

(kWt)

Engine Model

Engine Power

(kW)

Cyls.&

Type

Dspl.

(L)

Elec Eff. Heat Eff. Total Eff.

 PDF

D/L

 

※EW-400N6 400 427

TCG3016V08/

CG132-V8

436 8.V 17.5 42.1% 45.0% 87.1% click download pdf
EW-600N6 600 654

TCG3016V12/

CG132-V12

656 12.V 26.3 42.4% 45.7% 88.1% click download pdf
EW-800N6 800 856

TCG3016V16/

CG132-V16

820 16.V 35 42.6% 45.5% 88.1% click download pdf
※EW-1000N6 1000 1100

TCG2020V12K/

CG170-V12

1187 12.V 53.1 40.7% 45.6% 86.3% click download pdf
※EW-1125N6 1125 1261

TCG2020V12K/

CG170-V12

1187 12.V 53.1 40.7% 45.6% 86.3% click download pdf
EW-1200N6 1200 1189

TCG2020V12/

CG170-V12

1245 12.V 53.1 43.4%

43.2%

86.6% click download pdf
※EW-1500N6 1500 1686

TCG2020V16K/

CG170-V16

1557 16.V 70.8 40.6% 45.7% 86.3% click download pdf
EW-1560N6 1560 1576

TCG2020V16/

CG170-V16

1620 16.V 70.8 43.0% 43.8% 86.8% click download pdf
EW-2000N6 2000 2021

TCG2020V20/

CG170-V20

2079 20.V 88.5 43.4% 43.2% 86.6% click download pdf

 

Remarks:

• Above Gensets are based on 60Hz, 1800rpm, 480V, 3 Phases & 4 Wires.

• According to ISO3046-1 at U=0.48kV, cosphi=1.0 for 60Hz, methane number of natural gas>70, lower calorific value: LHV>36MJ/Nm³.

• Electrical efficiency is based on cosphi =1.0 and ISO3046 conditions. Heat is recovered from jacket water and exhaust gas cooled to 120℃.

• Operations conditions is based on ambient temperature -25-25℃ and altitude less than 1000m.

• For power deratings caused by other temps and altitudes, please consult Ettes Power.

• Other low voltages and high voltage of 4.16kV, 6.6kV and 13.8kV are available for options.

• Models with "N" for Natural gas (CNG, PNG, LNG, Shale Gas, Oilfield Associated Gas and Coalmine Gas etc).

• Special configurations for Soundproof Container, ATS and Synchronizing Parallel System are available for options.

• Special configuration of CHP, CCHP (trigeneration), Cogeneration are available for options. 

• All data provided on this site is for information purposes only, explicitly non-binding and subject to changes without further notice.

Typical Machinery Design

 Ettes Power Cummins Natural Gas Engine Generator Set CHP Ettespower  Ettes Power Cummins Natural Gas Engine Generator CHP Ettespower   Ettes Power Cummins Gas Engine Generator CHP Ettespower

Production Standards

  • Prevailing Industry Standards: ISO3046ISO8528GB2820, BS5000PT99,AS1359,IEC34, DIN6271, BS5514.
  • ISO Standards: ISO9001:2008, ISO14001, ISO45001 (former OHSAS 18001)
  • National & Regional Comformity Standards: CE, UL, EPA, CSA and SONCAP etc.
  • Third Party Verification: SGS, CCS, BV, ABS, and DNV-GL etc.  

World Top Materials of Gas Generator

  • Gas Engines: Cummins, MAN, MWM, CNPC
  • Alternators: Stamford AVK, Leroy Somer, ABB, Siemens, Marelli, or Mec calte
  • Control System: Deepsea, ComAp or DEIF
  • Air Circuit Breaker/Switchgear: ABB, Schneider, Eaton or Siemens
  • Governing Actuator: Germany Mototerch, Heinzmann, USA Woodward or Swiss Huegli
  • Air-Gas Mixer: Auto, Electrically controlled, Germany Motortech or Swiss Huegli
  • Ignition System: Germany Motortech, USA Altronic or Swiss Huegli
  • Key Materials of CHP System: Siemens, Alfa laval, Swep and Grundfos
  • Gas Train (safty valves): Germany Dungs, Chroms or Italy Madas
  • Tailored configuration: common soundproof canopy, 20 & 40 feet modular container, ATS/ACS system, synchronization parallel panel, remote control & Scada system, oil & cylinder water heater, anti-condensation heater (space heater), digital AVR, AREP/PMG system, IP44 protection level & B class temperature rise, high voltage alternator (3.3kV, 6.3kV, 10.5kV etc.), CHP (combined heat and power), CCHP and trigeneration etc.

Applicable Natural Gas Fuels

● PNG (Pipeline Natural Gas)      ● CNG(Compressed Natural Gas)
● LNG (Liquid natural gas)                                      ● Oilfield APG (Associated Petroleum Gas)
● Coalmine/ Coalbed Methane Gas     ● CBM (Coalbed Methane)
● Well Gas     ● Marsh Gas
● Shale Gas     ● Other Methane Based Gases

Natural Gas Fuel Requirements

Composition Abbr. Limits Remarks
Methane number MN >80 for natural gas For Lower value, please consult ETTES POWER
Calorific value Hμ,N Lower value of 36MJ/Nm³ Standard Calorific Value for Ettes Datasheet as per 
ISO8528/1, ISO3046/1 and BS5514/1.
Chlorine CL <80 mg / Nm³ CH4

For higher value, please consult ETTES POWER

Fluoride F <40 mg / Nm³ CH4 For higher value, please consult ETTES POWER
Total-chlorine Fluoride ∑(Cl,F) <80 mg / Nm³ CH4 For higher value, please consult ETTES POWER
Dust / <5μm or <10 mg / Nm³ CH4 For higher value, please consult ETTES POWER
Oil Vapor  / <400 mg / Nm³ CH4 No condensation may occur in the mixture section
Silicon Element Si <2 mg / Nm³ CH4 For higher value, please consult ETTES POWER
Sulphur S <200 mg / Nm³ For higher values, please consult ETTES POWER
Hydrogen Sulphide H2S <200 ppm or <304 mg / Nm³ For higher value, please consult ETTES POWER
Ammonia NH3 <40 ppm or<30 mg / Nm³ For other values, please consult ETTES POWER
Gas Pressure Range / 5kPa~20kPa For other values, please consult ETTES POWER
Gas Temperature / <30℃ For other values, please consult ETTES POWER

Typical Natural Gas Applications Fields

Application-Fields-of-Ettes-Power-Natural-GasTags: gas fired generator, gas fueled generator, natural gas cogeration, natural gas CHP, gas trigeneration, natural gas trigeneration, gas powered generator, natural gas generator, gas generator, gas generation, PNG Generator, cng generator, gas engine generator, gas generation, gas power generator, lng generator, natural gas engine, natural gas power generation, natural gas power plant, gas electric generator,gas powered generator, natural gas generator, gas power plant, gas cogeneration, gas chp. 

Overseas Market Sales Dept.

Add: No 188, Anshan West Road, Nankai District, Tianjin,  China

General Line: +86-22-23796980
Sales Line 01:+86-13672013688
Sales Line 02:+86-15620075781
FAX: +86-22-23796811
Email: sales@ettespower.com
           ettespower@gmail.com 
Skype No 1: ettespower
Skype No 2: ettes-power

Follow Us:

Quick Link

About Us

News & Projects

Download

Land Diesel Genset

EC-Cummins Series

202000kVa

EP-Perkins Series

102500kVa

ES-Mitsubishi Series

5002500kVa

ET-MTU Series

2503500kVa

Marine Diesel Genset

ECM-Cummins Series

40~1200kW

EHM-Deutz Series

100~3000kW

EMM-MAN Series

400~2000kW

Natural Gas Genset & CHPs

ECN-Cummins Series

40~1000kW

EMN-MAN Series

50~600kW

EWN-MWM Series

400~2300kW

EJN-CNPC Series

300~2000kW

Biogas Genset & CHPs

ECB-Cummins Series

30~500kW

EMB-MAN Series

60~600kW

EWB-MWM Series

400~2000kW


 

Syngas & Biomass Engines

EJS-CNPC Engine Series

200~500kW

EZS-Low Speed Engine Series

300~1000kW

Special Configurations

CHP & Cogeneration

Soundproof Canopy & CHP

Containerized Genset & CHP 

Moving Trailer

ATS Control System

Parallel & Synchronization

Intelligent Control System

High Voltage Generators

Share to :

Ettes Power Group © 2016 | All Rights Reserved | No 188, Anshan West Road, Tianjin, China | Tel: (86) 22-23796980 | Fax: (86) 22-23796811 | E-mail: info@ettespower.com